Product Construction:
Conductor: Tinned Copper
Insulation: ETFE&PFA&FEP&PTFE
Applications:
Internal wiring for LCD ( Liquid Crystal Display ) of electric equipment, such as notebook PCs, mobile phone, digital cameras etc.
Compliances:
Rating Temperature:105℃
Rating Voltage:30 Volts
Flammability: VW-1 Vertical Wire Flame Test
Standards:
Appliance Wiring Material UL 758 AWM (USA) UL 1581
Conductor | Insulation | Electrical Properties | |||||
AWG | Stranding | Outside | Thickness | Diameter | Max.Conductor. | Min.Insulation | Min.Dielectric Withstanding Voltage |
36 | 7/0.005 | 0.15 | 0.05 | 0.25 | 1500 | 1000 | 1000 |
34 | 7/0.06 | 0.18 | 0.07 | 0.32 | 955 | ||
32 | 7/0.08 | 0.24 | 0.07 | 0.38 | 588 | ||
30 | 7/0.10 | 0.30 | 0.10 | 0.50 | 376 | ||
28 | 7/0.127 | 0.38 | 0.11 | 0.60 | 237 | ||
26 | 7/0.16 | 0.48 | 0.10 | 0.68 | 148 |
Additional cross sections and conductor constructions can be supplied upon request.
Note:
ETFE= Ethylene tetrafluoroethylene
PFA= Polyfluoroalkoxy
FEP= Fluorinated ethylenepropylene
PTFE= Polytetrafluoroethylene